Product Name | 11996-000017 Electrode Pads For Physio-Control Lifepak 1000 Defibrillator |
Brand | Physio-Control |
Part No | 11996-000017 |
MOQ | One piece |
Warranty | 90 days |
Application | Physio-Control Lifepak 1000 Defibrillator |
Patient Type | Adult |
Patient Impedance Range | 10 – 300 ohms |
Use for | Hospital ,Clinic |
Condition | Original new |
Brand Name | Physio-Control |
Model Number | 11996-000017 |
View Detail Information
Explore similar products
REF 4-07-0001 Lithium MnO2 Battery 12V 2,8Ah for defibrillator Fred Easy
Heartstart Radiolucent Multifunction Electrode Defibrillation Pads Electrodes
PHILIP Heartstart XL M4735A Defibrillator Mainboard Keypad Screen Cable
Hospital Defibrillator Machine Parts 100-240V Power Supply
Product Specification
Payment Terms | T/T, Western Union,Paypal | Delivery Time | 3-5 working days |
Packaging Details | Carton | Product Name | 11996-000017 Electrode Pads For Physio-Control Lifepak 1000 Defibrillator |
Brand | Physio-Control | Part No | 11996-000017 |
MOQ | One piece | Warranty | 90 days |
Application | Physio-Control Lifepak 1000 Defibrillator | Patient Type | Adult |
Patient Impedance Range | 10 – 300 ohms | Use for | Hospital ,Clinic |
Condition | Original new | Brand Name | Physio-Control |
Model Number | 11996-000017 | ||
High Light | 11996-000017 Electrode Pads ,Defibrillator Electrode Pads ,Physio-Control Lifepak 1000 Electrode Pads |
Physio-Control Lifepak 1000 Defibrillator Pads 11996-000017
► About Physio-Control Lifepak 1000 Defibrillator
Defibrillation is a recognized method of stopping life-threatening arrhythmias. DC defibrillators send short, high-energy electrical pulses to the heart muscle. The LIFEPAK® 1000 defibrillator is an automated external defibrillator (AED) that delivers this energy through disposable defibrillation electrodes placed on the patient's chest.
Defibrillation is only one aspect of the medical care required to resuscitate a patient with a shockable EKG rhythm. Depending on the circumstances, additional measures may include:
• Cardiopulmonary resuscitation (CPR)
• Supplemental oxygen
• Drug treatment
Successful resuscitation is known to be related to the time between non-circulating heart rhythms (ventricular fibrillation, pulseless ventricular tachycardia) and defibrillation. The American Heart Association has identified the following critical links in the sudden cardiac arrest (SCA) survival chain:
• Early attention
• Early resuscitation by paramedics or bystanders.
• Early defibrillation
• Early advanced life support
With Adult Pads:
Patient Impedance Range: 10 – 300 ohms
The following specifications apply from 25 to 200 ohms.
Energy Accuracy:
10% of the energy setting into 50 ohms
15% of the rated energy output into 25 – 200 ohms
Rated energy output is the nominal delivered energy based on the energy setting and patient impedance, as defined in the following chart.
► TROUBLESHOOTING TIPS FOR DEFIBRILLATION
Observation | Possible Cause | Solutions |
CONNECT ELECTRODES voice prompt is heard. | Poor electrode-to-skin contact. Electrode pads are dry, damaged, or have passed the expiration date. Electrode pads are not removed from the liner. | • Firmly press electrodes on patient’s skin. • Clean, shave, and dry the patient’s skin prior to placing pads on skin • Replace the electrode pads. • Remove the electrode pads from the liner and apply them to the patient’s chest |
► Specification of Physio-Control Lifepak 1000 Defibrillator Pads 11996-000017
Product Name | Physiillatoro-Control Lifepak 1000 Defibr Pads 11996-000017 |
Brand | Physio-Control |
Part No | 11996-000017 |
Application | Physiillatoro-Control Lifepak 1000 Defibrallator |
MOQ | One piece |
Warranty | 90 days |
Condition | Original new |
Use for | Hospital ,Clinic etc |
Patient Type | Adult |
Thank you so much for your attention .If you're interested in 11996-000017 Electrode Pads For Physio-Control Lifepak 1000 Defibrillator ,feel free to contact us .Thank you .
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!