Payment Terms | T/T |
Supply Ability | 1piece in stock |
Delivery Time | 3 day |
Packaging Details | 120*80*50mm |
Weight[g] | 474 |
Dimensions[mm] | 110 x 45 x 72 |
System | gold-plated contacts |
Brand Name | IFM |
Model Number | SV4200 |
Certification | 3C |
Place of Origin | GERMANY |
View Detail Information
Explore similar products
IFM Inductive Full-metal Sensor II502A IIK3010-BPKG/AM/US104DPS/3G/3D Connector
Inductive Sensor IIS206 IIKC015BASKG/2LED Flush Mountable Connector 1 X M12
IIS238 Inductive Sensor IfmElectronic For Industrial Mobile Cooling And
IFM Electronic Gmbh Inductive Sensor IM0010 Non-flush Mountable
Product Specification
Payment Terms | T/T | Supply Ability | 1piece in stock |
Delivery Time | 3 day | Packaging Details | 120*80*50mm |
Weight[g] | 474 | Dimensions[mm] | 110 x 45 x 72 |
System | gold-plated contacts | Brand Name | IFM |
Model Number | SV4200 | Certification | 3C |
Place of Origin | GERMANY | ||
High Light | IFM SV4200 vortex flowmeter ,vortex flowmeter for water media ,IFM flowmeter with display |
Product characteristics | ||||||||||
Number of inputs and outputs | Number of digital outputs: 2 | |||||||||
Measuring range | 1...20 l/min | 0.06...1.2 m³/h | ||||||||
Process connection | threaded connection G 1/2 DN8 | |||||||||
Application | ||||||||||
Special feature | Gold-plated contacts | |||||||||
Application | for industrial applications | |||||||||
Media | water; glycol solutions; coolants | |||||||||
Medium temperature [°C] | -10...90 | |||||||||
Pressure rating [bar] | 12 | |||||||||
![]() | ||||||||||
SV4200 | ||||||||||
Vortex flow meter with display | ||||||||||
SVR12XXXIRKG/US-100 | ||||||||||
Pressure rating [Mpa] | 1.2 | |||||||||
Note on pressure rating | up to 40 °C | |||||||||
MAWP (for applications [bar] | 3.9 | |||||||||
according to CRN) | ||||||||||
Electrical data | ||||||||||
Operating voltage | [V] | 18...30 DC | ||||||||
Current consumption | [mA] | < 30 | ||||||||
Min. insulation resistance | [MΩ] | 100; (500 V DC) | ||||||||
Protection class | III | |||||||||
Reverse polarity protection | yes | |||||||||
Power-on delay time | [s] | < 3 | ||||||||
Inputs / outputs | ||||||||||
Number of inputs and outputs | Number of digital outputs: 2 | |||||||||
Outputs | ||||||||||
Total number of outputs | 2 | |||||||||
Output signal | switching signal; frequency signal; IO-Link; (configurable) | |||||||||
Electrical design | PNP/NPN | |||||||||
Number of digital outputs | 2 | |||||||||
Output function | normally open / normally closed; (parameterisable) | |||||||||
Max. voltage drop switching output DC | [V] | 2.5 | ||||||||
Permanent current rating of switching output DC | [mA] | 100 | ||||||||
Short-circuit protection | yes | |||||||||
Overload protection | yes | |||||||||
Measuring/setting range | ||||||||||
Measuring range | 1...20 l/min | 0.06...1.2 m³/h | ||||||||
Display range | 0...24 l/min | 0...1.44 m³/h | ||||||||
Resolution | 0.1 l/min | 0.005 m³/h | ||||||||
Set point SP | 1.2...20 l/min | 0.07...1.2 m³/h | ||||||||
Reset point rP | 1...19.8 l/min | 0.06...1.19 m³/h | ||||||||
Frequency endpoint, FEP | 4...20 l/min | 0.24...1.2 m³/h | ||||||||
Insteps of | 0.1 l/min | 0.005 m³/h | ||||||||
Frequency at the endpoint [Hz] | 100.. | .1000 | ||||||||
FRP | ||||||||||
Measuring dynamics | 1:20 | |||||||||
Temperature monitoring | ||||||||||
Measuring range | [°C] | -10...90 | ||||||||
Display range | [°C] | -30...110 | ||||||||
Resolution | [°C] | 0.5 | ||||||||
Set point SP | [°C] | -9...90 | ||||||||
Reset point rP | [°C] | -10...89 | ||||||||
Insteps of | [°C] | 0.5 | ||||||||
Frequency start point, FSP | [°C] | -10...70 | ||||||||
Frequency endpoint, FEP | [°C] | 10...90 | ||||||||
![]() | ||||||||||
SV4200 | ||||||||||
Vortex flow meter with display | ||||||||||
SVR12XXXIRKG/US-100 | ||||||||||
Frequency at the endpoint [Hz] | 100...1000 | |||||||||
FRP | ||||||||||
Accuracy / deviations Flow monitoring | ||||||||||
Accuracy (in the measuring range) | ± 2 % MEW; (water) | |||||||||
Repeatability | ± 0,5 % MEW | |||||||||
Temperature monitoring | ||||||||||
Accuracy [K] | ± 1 | |||||||||
Response times Flow monitoring | ||||||||||
Response time | [s] | 1; (dAP = 0) | ||||||||
Damping process value dAP | [s] | 0...5 | ||||||||
Temperature monitoring | ||||||||||
Dynamic response T05 / T09 [s] | T09 = 6 | |||||||||
Software / programming | ||||||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; frequency output; switch-on/switch-off delay; Damping; Display unit | |||||||||
Interfaces | ||||||||||
Communication interface | IO-Link | |||||||||
Transmission type | COM2 (38,4 kBaud) | |||||||||
IO-Link revision | 1.1 | |||||||||
SDCI standard | IEC 61131-9 | |||||||||
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | |||||||||
SIO mode | yes | |||||||||
Required master port type | A | |||||||||
Process data analogue | 2 | |||||||||
Process data binary | 2 | |||||||||
Min. process cycle time [ms] | 3 | |||||||||
Supported DeviceIDs | Type of operation | DeviceID | ||||||||
Default | 484 | |||||||||
Operating conditions | ||||||||||
Ambient temperature | [°C] | 0...60 | ||||||||
Note on ambient temperature | medium temperature < 80 °C | |||||||||
medium temperature < 90 °C: 0...50 °C | ||||||||||
Storage temperature | [°C] | -20...80 | ||||||||
Protection | IP 65; IP 67 | |||||||||
Tests / approvals | ||||||||||
EMC | DIN EN 61000-6-2 | |||||||||
DIN EN 61000-6-3 | ||||||||||
![]() | ||||||||||
SV4200 | ||||||||||
Vortex flow meter with display | ||||||||||
SVR12XXXIRKG/US-100 | ||||||||||
CPA approval | model number | 001VO | ||||||||
accuracy class | - | |||||||||
maximum allowable error | ± 2 % FS | |||||||||
Q (min) | 0,09 m³/h | |||||||||
Q (t) | 0,24 m³/h | |||||||||
Q (max) | 1,2 m³/h | |||||||||
Shock resistance | DIN EN 60068-2-27 | 5 g (11 ms) | ||||||||
Vibration resistance | DIN EN 60068-2-6 | with water / 10...50 Hz 1 mm | ||||||||
with water / 50...2000 Hz 2 g | ||||||||||
MTTF [years] | 342 | |||||||||
UL approval | UL Approval no. | I001 | ||||||||
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | |||||||||
Mechanical data | ||||||||||
Weight | [g] | 474 | ||||||||
Materials | stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U | |||||||||
Materials (wetted parts) | stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM | |||||||||
Tightening torque | [Nm] | 30 | ||||||||
Process connection | threaded connection G 1/2 DN8 | |||||||||
Remarks | ||||||||||
Remarks | MW = measured value | |||||||||
MEW = Final value of the measuring range | ||||||||||
Pack quantity | 1 pcs. | |||||||||
Electrical connection | ||||||||||
Connector: 1 x M12; coding: A; Contacts: gold-plated | ||||||||||
![]() | ||||||||||
SV4200 | ||||||||||
Vortex flow meter with display | ||||||||||
SVR12XXXIRKG/US-100 | ||||||||||
Connection | ||||||||||
![]() | ||||||||||
OUT1: Flow monitoring - switching output - frequency output - IO-Link | ||||||||||
OUT2: flow monitoring and temperature monitoring - switching output - frequency output | ||||||||||
colours to DIN EN 60947-5-2 Core colours : | ||||||||||
BK = black BN = brown BU = blue WH = white | ||||||||||
Diagrams and graphs | ||||||||||
Pressure loss | ![]() Q volumetric flow quantity | |||||||||
![]() | ||||||||||
SV4200 | ||||||||||
Vortex flow meter with display | ||||||||||
SVR12XXXIRKG/US-100 | ||||||||||
pressure rating (bar) | ![]() |
Company Details
Business Type:
Trading Company
Year Established:
2017
Total Annual:
300000-800000
Employee Number:
12~20
Ecer Certification:
Verified Supplier
Xiamen Zhicheng Automation Technology Co., Ltd Xiamen Zhicheng Automation Technology Co., Ltd. Still Working And Able To Shipping Worldwide.We Are The Supplier For Industrial Automation Spare Parts.we Specialize In Plc Module, Dcs Card Pieces, Esd System C... Xiamen Zhicheng Automation Technology Co., Ltd Xiamen Zhicheng Automation Technology Co., Ltd. Still Working And Able To Shipping Worldwide.We Are The Supplier For Industrial Automation Spare Parts.we Specialize In Plc Module, Dcs Card Pieces, Esd System C...
Get in touch with us
Leave a Message, we will call you back quickly!