Payment Terms | T/T |
Supply Ability | 1000/Month |
Delivery Time | 4W |
Packaging Details | WOODEN |
Cooling Capacity | 60-70KW |
Mounting | Floor Standing Units |
Condition | Brand New |
Type | Chilled water/Air cooling units |
After-sales service provided | Engineers available to service machinery overseas |
Voltage | 380/400 VAC,230 VAC,220V |
Warranty | 1 Year(12 month with no artificial damage) |
Name | Data Center Server Room Air Cooling Units |
Refrigerant | R22(R407C/R410A) |
Application | Computer Room,Printing factory, Office,Industrial,Heat recovery,adjust cold/heat/humidity |
Color | Black Grey White |
Power | 3N-380V-50Hz,220v/50hz/60hz |
Brand Name | Coolent |
Model Number | CYA T50 T60 T70 |
Certification | ISO/CE |
Place of Origin | China |
View Detail Information
Explore similar products
Floor Standing Data Center Precision Air Conditioner 100KW With High Dual-Fan
IDC Cooling System Precision Air Conditioning Units
70KW Precision Air Conditioning System , Precision Air Conditioning For Data
Technological Room Precision Air Conditioning Units , CRAC Air Conditioning Unit
Product Specification
Payment Terms | T/T | Supply Ability | 1000/Month |
Delivery Time | 4W | Packaging Details | WOODEN |
Cooling Capacity | 60-70KW | Mounting | Floor Standing Units |
Condition | Brand New | Type | Chilled water/Air cooling units |
After-sales service provided | Engineers available to service machinery overseas | Voltage | 380/400 VAC,230 VAC,220V |
Warranty | 1 Year(12 month with no artificial damage) | Name | Data Center Server Room Air Cooling Units |
Refrigerant | R22(R407C/R410A) | Application | Computer Room,Printing factory, Office,Industrial,Heat recovery,adjust cold/heat/humidity |
Color | Black Grey White | Power | 3N-380V-50Hz,220v/50hz/60hz |
Brand Name | Coolent | Model Number | CYA T50 T60 T70 |
Certification | ISO/CE | Place of Origin | China |
High Light | DC Precision Air Conditioning Syst ,70KW Precision Ac System ,R407C Precision Air Unit |
Precision Ac System For Constant Precise Environment Like Data Center And Computer Room
Product Introduction Computer room precision air conditioners are widely used in computer rooms, program-controlled exchange rooms, satellite mobile communication stations, large medical equipment rooms, laboratories, laboratories, precision electronic instrument production workshops and other high-precision environments. Coolnet precision air conditioners are mainly designed to meet the special process and specific environment requirements of precision equipment. Its purpose is to precisely control its temperature, humidity, etc., and the air volume is large, which can adapt to various changes in heat load.
Benefits | ![]() |
Applications
![]() |
|
Technical Features
| ![]() |
Air Supply Method
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |
Certificates
Factory Details
Packing & Delivery
Case
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
10,000,000.00-10,000,000.00
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th... Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th...
Get in touch with us
Leave a Message, we will call you back quickly!