Payment Terms | T/T,PAYONEER |
Supply Ability | 10EA,8weeks |
Delivery Time | 8 WEEKS |
Packaging Details | In Box |
BRAND | EMERSON ROSEMOUNT |
MODEL | 3051CFPDS010W1S0500D32AA1E5M5 |
CATEGORY | Integral Orifice Flow Meter |
SUPPLY | 0 to 621,60 mbar |
Measurement type | Differential pressure |
Delivery time | 8 weeks |
Brand Name | ROSEMOUNT |
Model Number | 3051CFPDS010W1S0500D32AA1E5M5 |
Place of Origin | Singapore |
Certification | Does not supply |
View Detail Information
Explore similar products
STD924-E1H-00000-H6,SM,ZS,(CC),TG,S2,MB,F1,W2,1C+XXXX Differential Pressure
3051L2AA0D21AAF1 Rosemount 3051 Flow Meter Transmitter Rosemount Level
3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter
3051CD2A22A1AB4 Pressure Temperature Transmitter 4-20mA New In Box
Product Specification
Payment Terms | T/T,PAYONEER | Supply Ability | 10EA,8weeks |
Delivery Time | 8 WEEKS | Packaging Details | In Box |
BRAND | EMERSON ROSEMOUNT | MODEL | 3051CFPDS010W1S0500D32AA1E5M5 |
CATEGORY | Integral Orifice Flow Meter | SUPPLY | 0 to 621,60 mbar |
Measurement type | Differential pressure | Delivery time | 8 weeks |
Brand Name | ROSEMOUNT | Model Number | 3051CFPDS010W1S0500D32AA1E5M5 |
Place of Origin | Singapore | Certification | Does not supply |
High Light | 40mm Pressure Temperature Transmitter ,62160 mbar Pressure Temperature Transmitter ,3051CFP |
3051CFPDS010W1S0500D32AA1E5M5 Integral Orifice Flow Meter 3051CFP Transmitter
Product Information Of : 3051CFPDS010W1S0500D32AA1E5M5
Brand | 3051CFPDS010W1S0500D32AA1E5M5 |
SUPPLY | 0 to 621,60 mbar |
SIZE | No |
Weight | Does not supply |
Rosemount 3051CFP Integral Orifice Flow Meters enable highly accurate flow measurement in small line sizes. Integral Orifice Flow Meters use precision honed pipe section for increased accuracy and self-centering plate design to prevent alignment errors that magnify measurement inaccuracies in small line sizes.
■Up to 1.75 percent of flow rate accuracy.
■Available in ½- to 1½-in. (15 - 40 mm) line sizes.
■Fully assembled and leak tested for out-of-the-box installation.
■The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
■LOI with straightforward menus and built-in configuration buttons (option code M4).
More options :
SGDA-04BS
SGDA-04VP
SGDA-04VP
SGDA-04VS
SGDA-05ADG+SGMG-05A2A
SGDA-08AP
SGDA-08APP
SGDA-08APPY128
SGDA-08AS
SGDA-08ASP
SGDA-08ASP SGDA-08AS
SGDA-08VP
SGD-A3AN
SGD-A5AN
SGD-A5BH
SGDA-A3AP
SGDA-A3BPM
SGDA-A3BS
SGDA-A3BS
SGDA-A3CPY14
MR-J2S-350B-EG117
MDS-B-SVJ2-01
MDS-B-SVJ2-03
MDS-B-SVJ2-04
MDS-B-SVJ2-06
MDS-B-SVJ2-10
MDS-B-SVJ2-20
MDS-B-SVJ2-07
MDS-D-SVJ3-01NA
MDS-D-SVJ3-02NA
MDS-D-SVJ3-07NA
MDS-D-SVJ3-10NA
MDS-D-SVJ3-20NA
Rosemount 3051CFP Integral Orifice Flow Meter Information:
Model | Product description | |
3051CFP | Integral orifice flow meter | |
Measurement type | ||
D | Differential pressure | ★ |
Body material | ||
S | 316 SST | ★ |
Line size | ||
005 | ½-in. (15 mm) | ★ |
010 | 1-in. (25 mm) | ★ |
015 | 1½-in. (40 mm) | ★ |
Process connection | ||
T1 | NPT female body (not available with remote thermowell and RTD) | ★ |
S1(1) | Socket weld body (not available with remote thermowell and RTD) | ★ |
P1 | Pipe ends: NPT threaded | ★ |
P2 | Pipe ends: beveled | ★ |
D1 | Pipe ends: Flanged, DIN PN16, slip-on | ★ |
D2 | Pipe ends: Flanged, DIN PN40, slip-on | ★ |
D3 | Pipe ends: Flanged, DIN PN100, slip-on | ★ |
W1 | Pipe ends: Flanged, RF, ANSI Class 150, weld-neck | ★ |
W3 | Pipe ends: Flanged, RF, ANSI Class 300, weld-neck | ★ |
W6 | Pipe ends: Flanged, RF, ANSI Class 600, weld-neck | ★ |
A1 | Pipe ends: Flanged, RF, ANSI Class 150, slip-on | |
A3 | Pipe ends: Flanged, RF, ANSI Class 300, slip-on | |
A6 | Pipe ends: Flanged, RF, ANSI Class 600, slip-on | |
R1 | Pipe ends: Flanged, RTJ, ANSI Class 150, slip-on | |
R3 | Pipe ends: Flanged, RTJ, ANSI Class 300, slip-on | |
R6 | Pipe ends: Flanged, RTJ, ANSI Class 600, slip-on | |
Orifice plate material | ||
S | 316 SST | ★ |
H | Alloy C-276 | |
M | Alloy 400 | |
Bore size option | ||
0066 | 0.066-in. (1.68 mm) for ½-in. pipe | ★ |
0109 | 0.109-in. (2.77 mm) for ½-in. pipe | ★ |
0160 | 0.160-in. (4.06 mm) for ½-in. pipe | ★ |
0196 | 0.196-in. (4.98 mm) for ½-in. pipe | ★ |
0260 | 0.260-in. (6.60 mm) for ½-in. pipe | ★ |
0340 | 0.340-in. (8.64 mm) for ½-in. pipe | ★ |
0150 | 0.150-in. (3.81 mm) for 1-in. pipe | ★ |
0250 | 0.250-in. (6.35 mm) for 1-in. pipe | ★ |
0345 | 0.345-in. (8.76 mm) for 1-in. Pipe | ★ |
0500 | 0.500-in. (12.70 mm) for 1-in. pipe | ★ |
0630 | 0.630-in. (16.00 mm) for 1-in. pipe | ★ |
0800 | 0.800-in. (20.32 mm) for 1-in. pipe | ★ |
0295 | 0.295-in. (7.49 mm) for 1½-in. pipe | ★ |
0376 | 0.376-in. (9.55 mm) for 1½-in. pipe | ★ |
0512 | 0.512-in. (13.00 mm) for 1½-in. pipe | ★ |
0748 | 0.748-in. (19.00 mm) for 1½-in. pipe | ★ |
1022 | 1.022-in. (25.96 mm) for 1½-in. pipe | ★ |
1184 | 1.184-in. (30.07 mm) for 1½-in. pipe | ★ |
0010 | 0.010-in. (0.25 mm) for ½-in. pipe | |
0014 | 0.014-in. (0.36 mm) for ½-in. pipe | |
0020 | 0.020-in. (0.51 mm) for ½-in. pipe |
0034 | 0.034-in. (0.86 mm) for ½-in. pipe | ||
Transmitter connection platform | |||
D3 | Direct-mount, 3-valve manifold, SST | ★ | |
D5 | Direct-mount, 5-valve manifold, SST | ★ | |
R3 | Remote-mount, 3-valve manifold, SST | ★ | |
R5 | Remote-mount, 5-valve manifold, SST | ★ | |
D4 | Direct-mount, 3-valve manifold, alloy C-276 | ||
D6 | Direct-mount, 5-valve manifold, alloy C-276 | ||
D7 | Direct-mount, high temperature, 5-valve manifold, SST | ||
R4 | Remote-mount, 3-valve manifold, alloy C-276 | ||
R6 | Remote-mount, 5-valve manifold, alloy C-276 | ||
Differential pressure ranges | |||
1 | 0 to 25 in H2O (0 to 62,16 mbar) | ★ | |
2 | 0 to 250 in H2O (0 to 621,60 mbar) | ★ | |
3 | 0 to 1000 in H2O (0 to 2,48 bar) | ★ | |
Transmitter output | |||
A(2) | 4–20 mA with digital signal based on HART® Protocol | ★ | |
F | FOUNDATION™ Fieldbus Protocol | ★ | |
W(3) | PROFIBUS® PA Protocol | ★ | |
X(4) | Wireless | ★ | |
M(5) | Low-power 1–5 Vdc with digital signal based on HART Protocol | ||
Transmitter housing material | Conduit entry size | ||
A | Aluminum | ½–14 NPT | ★ |
B | Aluminum | M20 x 1.5 | ★ |
E | Aluminum, ultra low copper | ½–14 NPT | |
F | Aluminum, ultra low copper | M20 x 1.5 | |
J | SST | ½–14 NPT | ★ |
K | SST | M20 x 1.5 | ★ |
P(6) | Engineered polymer | No conduit entries | ★ |
D(7) | Aluminum | G½ | |
M(7) | SST | G½ | |
Transmitter performance class | |||
1 | up to ±1.8% flow rate accuracy, 8:1 flow turndown, 5-year stability | ★ | |
Wireless options (requires wireless output code X and engineered polymer housing code P) | |||
Wireless transmit rate, operating frequency, and protocol | |||
WA3 | User configurable transmit rate, 2.4GHz WirelessHART | ★ |
Antenna and SmartPower | ||
WP5 | Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately) | ★ |
Options (include with selected model number) | ||
Extended product warranty | ||
WR3 | 3-year limited warranty | ★ |
WR5 | 5-year limited warranty | ★ |
Transmitter body/bolt material | ||
GT | High temperature (850 °F/454 °C) | |
Temperature sensor(8) | ||
RT | Thermowell and RTD | |
Optional connection | ||
G1 | DIN 19213 transmitter connection | ★ |
Pressure testing(9) | ||
P1 | Hydrostatic testing with certificate | |
Special cleaning | ||
P2 | Cleaning for special services | |
PA | Cleaning per ASTM G93 level D (section 11.4) | |
Material testing | ||
V1 | Dye penetrant exam | |
Material examination | ||
V2 | Radiographic examination | |
Flow calibration(10) | ||
WD | Discharge coefficient verification | |
Special inspection | ||
QC1 | Visual and dimensional inspection with certificate | ★ |
QC7 | Inspection and performance certificate | ★ |
Material traceability certification | ||
Q8 | Material traceability certification per EN 10204:2004 3.1 | ★ |
Code conformance(11) | ||
J2 | ANSI/ASME B31.1 | |
J3 | ANSI/ASME B31.3 | |
J4 | ANSI/ASME B31.8 | |
Materials conformance(12) | ||
J5 | NACE MR-0175/ISO 15156 | |
Country certification | ||
J6 | European Pressure Directive (PED) | ★ |
J1 | Canadian Registration | |
Transmitter calibration certification | ||
Q4 | Calibration Certificate for Transmitter | ★ |
Quality certification for safety(13) | ||
QS | Prior-use certificate of FMEDA data | ★ |
QT | Safety certified to IEC 61508 with certificate of FMEDA | ★ |
Product certifications | ||
E8 | ATEX Flameproof, Dust | ★ |
I1(14) | ATEX Intrinsic Safety and Dust | ★ |
IA | ATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only | ★ |
N1 | ATEX Type n and Dust | ★ |
K8 | ATEX Flameproof, Intrinsic Safety, Type n, and Dust (combination of E8, I1, and N1) | ★ |
E5 | FM Explosion-proof, Dust Ignition-proof | ★ |
I5(15) | FM Intrinsically Safe, Nonincendive | ★ |
IE | FM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only | ★ |
K5 | FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of E5 and I5) | ★ |
C6 | CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 | ★ |
I6 (6) | CSA Intrinsically Safe | ★ |
K6 | CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1) | ★ |
E7 | IECEx Flameproof, Dust Ignition-proof | ★ |
I7 | IECEx Intrinsic Safety | ★ |
N7 | IECEx Type n | ★ |
K7 | IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7) | ★ |
E2 | INMETRO Flameproof | ★ |
I2 | INMETRO Intrinsic Safety | ★ |
IB | INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only | ★ |
K2 | INMETRO Flameproof, Intrinsic Safety | ★ |
E3 | China Flameproof | ★ |
I3 | China Intrinsic Safety | ★ |
KB | FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of K5 and C6) | ★ |
KD | CSA, FM, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8) | ★ |
Sensor fill fluid and O-ring options | ||
L1(16) | Inert sensor fill fluid | ★ |
L2 | Graphite-filled (PTFE) O-ring | ★ |
LA(16) | Inert sensor fill fluid and graphite-filled (PTFE) O-ring | ★ |
Shipboard approvals(16) | ||
SBS | American Bureau of Shipping | ★ |
SLL(17) | Lloyds Register (LR) | |
Display and interface options | ||
M4(18) | LCD display with LOI | ★ |
M5 | LCD display | ★ |
Transient protection(16)(19) | ||
T1 | Transient terminal block | ★ |
Plantweb™ control functionality(20) | ||
A01 | FOUNDATION Fieldbus control function block suite | ★ |
Plantweb diagnostic functionality | ||
DA0(13) | Loop Integrity HART Diagnostic | ★ |
D01(20) | FOUNDATION Fieldbus diagnostic suite | ★ |
Low power output | ||
C2 | 0.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only) | |
Alarm levels(13) | ||
C4(21) | NAMUR alarm and saturation levels, high alarm | ★ |
CN(21) | NAMUR alarm and saturation levels, low alarm | ★ |
CR | Custom alarm and saturation signal levels, high alarm | ★ |
CS | Custom alarm and saturation signal levels, low alarm | ★ |
CT | Rosemount standard low alarm | ★ |
Ground screw(16) (22) | ||
V5 | External ground screw assembly | ★ |
Configuration buttons | ||
D4(13) | Analog zero and span | ★ |
DZ(23) | Digital zero trim | ★ |
Hart Revision configuration (requires HART Protocol output code A)(2) | ||
HR5 | Configured for HART Revision 5 | ★ |
HR7 | Configured for HART Revision 7 | ★ |
Typical model number: 3051CFP D S 010 W1 S 0500 D3 2 A A 1 E5 M5 |
Good Service in WTL:
> We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
> Please send your RFQ to get the latest price.
> Normally, we will ship the items in 1-2 weeks after receive the payment.
> We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
> We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.
If needed, please contact us for specific prices.
OUR MAIN BRAND:
Company Details
Business Type:
Distributor/Wholesaler,Trading Company,Seller
Year Established:
2009
Total Annual:
100000-200000
Employee Number:
15~30
Ecer Certification:
Active Member
Wisdomlong Technology CO.,LTD locats at the central of China,Shenzhen, Guangdong Province. With rapid development, Wisdomlong serves fields of automation in global markets, Our business covers five continents throughout the world with the basic convicti... Wisdomlong Technology CO.,LTD locats at the central of China,Shenzhen, Guangdong Province. With rapid development, Wisdomlong serves fields of automation in global markets, Our business covers five continents throughout the world with the basic convicti...