China factories

China factory - Xi'an Yunyi Instrument Co., Ltd

Xi'an Yunyi Instrument Co., Ltd

  • China
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China MF4000 Gas Mass Flow Meter: High-Accuracy MEMS-Based Measurement for Medical,
China MF4000 Gas Mass Flow Meter: High-Accuracy MEMS-Based Measurement for Medical,

  1. China MF4000 Gas Mass Flow Meter: High-Accuracy MEMS-Based Measurement for Medical,
  2. China MF4000 Gas Mass Flow Meter: High-Accuracy MEMS-Based Measurement for Medical,
  3. China MF4000 Gas Mass Flow Meter: High-Accuracy MEMS-Based Measurement for Medical,
  4. China MF4000 Gas Mass Flow Meter: High-Accuracy MEMS-Based Measurement for Medical,

MF4000 Gas Mass Flow Meter: High-Accuracy MEMS-Based Measurement for Medical,

  1. MOQ: 1 Piece
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 1000-5000pcs
Delivery Time 10 work days
Packaging Details cardboard box
Brand Name YUNYI
Model Number MF4000
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 1000-5000pcs
Delivery Time 10 work days Packaging Details cardboard box
Brand Name YUNYI Model Number MF4000
Certification CE Place of Origin China

MF4000 Gas Mass Flow Meter

The MF4000 Series is a advanced gas mass flow meter designed for low-flow gas measurement in pipelines with diameters of 3 mm to 8 mm. It utilizes Micro-Electro-Mechanical Systems (MEMS) thermal sensor technology to provide accurate and reliable mass flow measurements without requiring temperature or pressure compensation. Suitable for a wide range of industrial and medical applications, it offers high precision, excellent repeatability, and flexible output options.

 


Technical Parameters

The key specifications for the MF4000 series (with models MF4003 for 3mm diameter and MF4008 for 8mm diameter) are summarized in the table below:

 
 
Parameter / Feature MF4003 MF4008 Unit(s)
Pipe Diameter 3 8 mm
Max Flow Rate (Range) 2, 3, 4, 5 10, 20, 30, 40, 50 SLPM
Accuracy ±(1.5 + 0.2FS)% ±(1.5 + 0.2FS)% %
Repeatability 0.25% 0.25% %
Response Time 10 (default, configurable) 10 (default, configurable) ms
Power Supply 8~24 VDC, 50mA 8~24 VDC, 50mA -
Output Options RS232, RS485, 0.5~4.5 VDC RS232, RS485, 0.5~4.5 VDC -
Operating Pressure ≤0.5 ≤0.5 MPa
Operating Temperature -10 to +55 -10 to +55 °C
Mechanical Connection BSPT 1/4", 4/6/8mm BSPT 1/4", 4/6/8mm -
Display & Interface 4-digit LED, buttons for config 4-digit LED, buttons for config -

Key Features & Advantages

The MF4000 series stands out due to several important features:

High Precision & Wide Rangeability: Offers an accuracy of ±(1.5+0.2FS)% and a impressive 100:1 turndown ratio, allowing for reliable measurement across a broad flow range.

MEMS Sensor Technology: The core MEMS thermal sensor provides fast response times (as low as 10 ms), high stability, and measures mass flow directly, eliminating the need for external temperature or pressure compensation.

Flexible Output & Communication: Provides multiple output options including analog voltage (0.5~4.5 VDC), RS232, and RS485, facilitating easy integration into various control and monitoring systems.

User-Friendly Design: Features an LED display for showing instantaneous and cumulative flow, and allows for on-site parameter configuration via buttons.

Compact & Versatile Installation: Its compact design and multiple available connection types (threaded or quick-connect) make it easy to install in diverse applications and space-constrained environments.

Low Power Consumption: With a typical requirement of 50 mA, it is suitable for applications where power efficiency is important, including potentially battery-operated systems.

 


Typical Applications

The MF4000 gas mass flow meter is versatile and is commonly used in:

Medical & Healthcare Equipment: Anesthesia machines, ventilators, respiratory devices, hospital oxygen supply systems, and patient monitoring.

Industrial Process Control & Automation: Monitoring and controlling gas flow (e.g., compressed air, O₂, N₂, H₂, He) in various manufacturing and processing applications.

Environmental Monitoring & Analysis: Air samplers, gas analyzers, and other equipment used for environmental detection and emission monitoring.

Laboratory & Analytical Instruments: Particle counters, spectrometers, and other precision instruments requiring accurate gas flow measurement.

General Purpose Low-Flow Gas Measurement: Any application involving low flow rates of clean, dry gases in small diameter pipes where reliable data is critical.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2007

  • Total Annual:

    1000000-2000000

  • Employee Number:

    150~200

  • Ecer Certification:

    Verified Supplier

YUN YI ,we are professional manufacturer that engaged in the fields of pressure measurement instrument. we have 12 years sensor producing and developing experiences Xi'an Yunyi Instrument Co., Ltd is a professional R&D center and manufacture of measuring instruments.And here's a vari... YUN YI ,we are professional manufacturer that engaged in the fields of pressure measurement instrument. we have 12 years sensor producing and developing experiences Xi'an Yunyi Instrument Co., Ltd is a professional R&D center and manufacture of measuring instruments.And here's a vari...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Yunyi Instrument Co., Ltd
  • Rm. 1203-1, Bldg. B, Xian Xinsilu International E-Commerce Industrial Park, No. 9, Gangwu Road, Int'l Port District
  • https://www.transmitterpressuresensor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement