China 4-20mA IP68 Doppler Ultrasonic Flow Meter
China 4-20mA IP68 Doppler Ultrasonic Flow Meter

  1. China 4-20mA IP68 Doppler Ultrasonic Flow Meter

4-20mA IP68 Doppler Ultrasonic Flow Meter

  1. MOQ: 1 Unit
  2. Price: Negotiable
  3. Get Latest Price
Supply Ability 1000 Unit/Units per Week Doppler Ultrasonic Flow Meter of Wall-mounted Series is for OEM
Packaging Details Packing: 1unit/carton
Product Name Doppler Ultrasonic Flow Meter of Wall-mounted Series
Accuracy 0.5%-2.0% F.S.
Repeatability 0.25%mm/s
Velocity range 0.05- 12 m/s
Housing material Fiberglass
Liquid Types Supported Liquids containing 100ppm of reflectors and at least 20% of the reflectors are larger than 100 micron.
Place of Origin Shanghai, China (Mainland)
Brand Name LANRY
Model Number DF6100-EC
Certification CE

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 1000 Unit/Units per Week Doppler Ultrasonic Flow Meter of Wall-mounted Series is for OEM Packaging Details Packing: 1unit/carton
Product Name Doppler Ultrasonic Flow Meter of Wall-mounted Series Accuracy 0.5%-2.0% F.S.
Repeatability 0.25%mm/s Velocity range 0.05- 12 m/s
Housing material Fiberglass Liquid Types Supported Liquids containing 100ppm of reflectors and at least 20% of the reflectors are larger than 100 micron.
Place of Origin Shanghai, China (Mainland) Brand Name LANRY
Model Number DF6100-EC Certification CE
High Light doppler type ultrasonic flow meterpolysonics doppler flow meter

DF6100-EC Doppler Ultrasonic Flow Meter of Wall-mounted Series

 

The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays for Totalizer and Alarm outputs. DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

 

DF6100-EC Doppler Ultrasonic Flow Meter of Wall-mounted Series Features:

 

1. It is suitable for pipe sizes ranging from 40 to 4000mm

2. For dirty liquids, a certain amount of air bubbles or suspended solids shall be contained

3. A wide range of flow measurement, high flow rate can reach 12m/s

4. Do not need to shut down the pipe flow when installing the transducers

5. Accuracy: 2.0% Calibrated span 

6. User-friendly configuration

 

Specifications: Transmitter

 

Measurement principle Doppler ultrasonic
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy 0.5% -- 2.0% F.S.
Response time 2-60s for optional
Flow Velocity Range 0.05- 12 m/s
Liquid Types Supported Liquids containing 100ppm of reflectors and at least 20% of the reflectors are larger than 100 micron.
Degree of protection IP66 according to EN60529
Operating temperature -20℃ to +60℃
Display 2 line × 8 characters LCD, 8-digit rate or 8-digit total (resettable)
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Communication 4-20mA,relays for Totalizer and alarm output
Size 244(h)*196(w)*144(d)mm
Weight 2.4kg

 

 

Specifications: Transducer

 

Transducers Type Clamp-on
Degree of protection IP65. IP67 or IP68 according to EN60529
Suited Liquid Temperature Std. Temp.: -35℃~85℃ for short periods up to 120℃
Pipe diameter range 25-4000 mm
Transducer Size 60(h)*34(w)*32(d)mm
Material of transducer Stainless steel
Cable Length Std: 10m

 

 

 

 

 

Application

 

 

 

 

 

 

 

 

Company

 

 

Company profile

 

Lanry Instruments  is the professional manufacturer of flow detection instruments,  provides one package service of re-search and development, production, marketing and after-sales services. Engaged in the production of flow instruments more than 20 years,  Lanry has been equipped  with advanced  design capabilities  and piled up a wealth of field application experience, which lays solid foundation for the commitment to the promotion and innovation of high-tech system solution. The corporation has devoted to the production of flow measurement instruments with superior performance, high stability and strong reliability.

 

Packing for Transportation

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support all over the world.

 

 

Delivery by Express

 

Smart oil level gauge Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea canbe optional. 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2003

  • Total Annual:

    3000000-8000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Active Member

Lanry Instruments, is the professional manufacturer of flow measure instruments, provides one package service of research and development, production, marking and after-sales servica. Engaged in the production of flow meters more than 20 years, Lanry has been equipped with advanced design capabiliti... Lanry Instruments, is the professional manufacturer of flow measure instruments, provides one package service of research and development, production, marking and after-sales servica. Engaged in the production of flow meters more than 20 years, Lanry has been equipped with advanced design capabiliti...

+ Read More

Get in touch with us

  • Reach Us
  • Lanry Instruments (Shanghai) Co., Ltd.
  • 8 Floor, Block C, Bldg 5, No.2800 Jiuxin Rd., Songjiang District, Shanghai,201612, China
  • https://ultraflowmeter.ecer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement