Payment Terms | T/T, Western Union |
Delivery Time | 2-4 work days |
Packaging Details | Neutral Package |
Category | repair medical equipment |
Service | medical repair |
Warranty | 60 days after fixed |
Condition | Oringal |
Item | patient supplies |
Brand Name | Aixplorer |
View Detail Information
Explore similar products
Preirus Troubleshoot Ultrasound Machine Repair Hitachi Aloka
S2000 Color Doppler Medical Machine Repair For Startup Failure
GE Clinic Ultrasound Machine Repair
EPIQ 7 Ultrasound Machine Repair
Product Specification
Payment Terms | T/T, Western Union | Delivery Time | 2-4 work days |
Packaging Details | Neutral Package | Category | repair medical equipment |
Service | medical repair | Warranty | 60 days after fixed |
Condition | Oringal | Item | patient supplies |
Brand Name | Aixplorer | ||
High Light | Aixplorer Ultrasound Machine Repair ,Self Test Ultrasound Machine Repair |
Aixplorer Ultrasound Machine Repair Self-Test Failed And Unable To Enter The System
1. Repair time: 2-4 days
2. Warranty: 60 days
3. Fault phenomenon:
This fault is generally a front-end and back-end communication problem. Consider the channel board and its connecting wires
Repair result: Unplug and plug the connection cable from the channel board to the PC, and the fault is eliminated
Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range.
Other ultrasound parts related to GE that we can offer:
GE | vivid E9 | BEP Power P/N::GA200040 or 5145000-10 |
GE | vivid E9 | Main Power P/N::GA200004 |
GE | vivid E9 | Control Panel |
GE | Logiq E9/vivid E9 | GTX 2.4/GTX-TLP 3.0:5201044-3,5201044-4, 5201044-5 / GA200625-3 |
GE | Logiq E9 | MRX Board P/N:5393908 |
GE | Logiq E9/vivid E9 | GFI2 P/N:25161631 |
GE | Logiq E9 | BEP Power 5393800-3,5166790-2/5393801 |
GE | Logiq E9 | Main Power P/N:: 5205052-3 |
Logiq E9 | Control Panel board 9375-00639-001/2 | |
GE | Logiq E9/vivid E9 | Touch ScreenCORE OPERATOR PANEL, UPPER 4- touch panel GB200091/5207000-53 |
GE | Logiq E9 | Trackball |
GE | Logiq E9 | GE Logiq E9 19" LCD 5392293-21, KT-LM190SDG-U |
GE | Voluson E6/E8 | RSR14.P9 KTI196357 |
GE | Voluson E6/E8 | RST20.P8 KTI301148_2 |
GE | Voluson E6/E8/E10 | RSX |
GE | Voluson E6/E8/E10 | RFM201 FE mainboard |
GE | Voluson E6/E8/E10 | RFM221 FE mainboard |
GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board KTI300614_4 /KTI302197_6, RFI6g.P4 :KTI196142 |
GE | Voluson E6/Voluson E9 | KTI302171-4 |
GE | Voluson E6/Voluson E8 | RSR P/N:KTI301394-2/KTI196357/KTZ196310 |
GE | Voluson E6/Voluson E8 | AC/DC Power P/N:KTI300627-4/KTI300242-3 |
GE | Voluson E6/Voluson E8 | RSP2.PX EC250 Power P/N: KTZ302752 |
GE | Voluson E6/Voluson E8 | GBF80A KTI300741 |
GE | Voluson E6/Voluson E8 | GE Voluson E8 C2D E6400 BEP Board P/N KTI302072 |
Knowledge point
Aixplorer® Ultimate is a premium ultrasound system leveraging the unique UltraFast™ technology in which the frame rate is 200 times faster than conventional ultrasound systems. Its software-based architecture has allowed SuperSonic Imagine to continuously offer innovative and increasingly efficient imaging modes.
Our pioneering technology, ShearWave™ Elastography (SWE), is the only technique capable of non-invasively measuring tissue stiffness in a wide range of clinical applications and with all probes in real-time.
With Aixplorer Ultimate, you can enjoy innovation exponentially: everything works faster and even better.
Exceptional image quality
SuperSonic Imagine's UltraFast software technology provides a high quality, homogeneous and information-rich image for a wide variety of clinical situations. Also, thanks to TissueTuner™ technology, the speed of the ultrasound can be adapted for multiple organs and is well suited for a variety of clinical situations.
The only real-time ShearWave Elastography
Real-time ShearWave Elastography, pioneered by SuperSonic Imagine, allows physicians to visualize and quantify the stiffness of tissue in a real-time, reliable, and reproducible manner. Tissue stiffness has become an important parameter in diagnosing potentially malignant tissue or other diseased tissue. Almost 400 peer-reviewed publications have demonstrated the value of SWE for the clinical management of patients in a wide range of diseases.
Precautions for Maintenance
Before delivery, we'd like to confirm the below details of your defective ultrasonic board.
Have your board ever repaired? ( Better to be never repaired)
Is the board original in complete condition?
What's the detailed faults? ( Send me fault description, fault image or video)
Your answers will help our repair engineers team to prejudge whether it's repairable.
Company Details
Business Type:
Distributor/Wholesaler,Exporter,Trading Company,Seller
Year Established:
2014
Total Annual:
5,000,000-10,000,000
Employee Number:
50~60
Ecer Certification:
Active Member
Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex... Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex...
Get in touch with us
Leave a Message, we will call you back quickly!