Payment Terms | T/T, Western Union |
Delivery Time | 2-5 work days |
Packaging Details | Neutral Package |
Category | Chinese ultrasound product |
Service | Outright sale |
Warranty | 90 days |
Purpose | apply in hospital |
Conidition | Compatible |
Descriptionchinese ultrasound machine | needle guides |
Brand Name | Biosound Biosound |
Model Number | PA240 |
View Detail Information
Explore similar products
Ultrasound Biopsy Needle Guides for RIC5 9 D
GE 7L Transducer Guided Ultrasound Biopsy SS 90 Days Warranty
65° Ultrasound Biopsy Needle Guide For Samsung Medison CF4-9 Transducer
3 Angles Ultrasound Biopsy Needle Guide For Biosound LA332 Transducer
Product Specification
Payment Terms | T/T, Western Union | Delivery Time | 2-5 work days |
Packaging Details | Neutral Package | Category | Chinese ultrasound product |
Service | Outright sale | Warranty | 90 days |
Purpose | apply in hospital | Conidition | Compatible |
Descriptionchinese ultrasound machine | needle guides | Brand Name | Biosound Biosound |
Model Number | PA240 | ||
High Light | 65° Ultrasound Biopsy Needle Guide ,PA240 Transducer Ultrasound Biopsy Needle Guide |
Ultrasound Biopsy Needle Guides for Biosound PA240 Transducer
1. Type:25-65°, accepts 16,17,18 Gauge instruments
2. Fits:Biosound PA240
3. Features:stainless steel, reusable, easy to clean and sterilize
4. Professional new one from Chinese factory, precision manufacturing
5. Qualified one in excellent working condition
6. Provide 90 days warranty
Other needle guides for Biosound system that we can offer:
Brand | Model | Angle | Applicative needle |
Biosound | CA123 | two angles | 16,18G |
Biosound | CA421,CA430,CA431 | two angles | 16,18G |
Biosound | EC123,EC1123 | single angle | 16,17,18G |
Biosound | LA332 | three angles | 16,18G |
Biosound | LA522,LA523,LA532 | three angles | 16,18G |
Biosound | PA230E | 45-90° | 16,17,18G |
Biosound | TRT33 | single angle | 14,16,18,20G |
Biosound | CA541 | three angles | 14-22G |
Biosound | CA631 | two angles | 16,18G |
Biosound | PA240 | 25-65° | 16,17,18G |
Knowledge point
What is Ultrasound Biopsy Needle Guides
An ultrasound-guided biopsy is typically performed under general anesthesia. Ultrasound is used to locate the abnormality and a biopsy needle guide is used to pinpoint and guide the needle to the exact location. The tissue that is collected in the ultrasound guided needle biopsy is then examined by a pathologist.
Lumps or abnormalities in the breast are often detected by physical examination, mammography, or other imaging studies. However, it is not always possible to tell from these imaging tests whether a growth is benign or cancerous.
A breast biopsy is performed to remove some cells from a suspicious area in the breast and examine them under a microscope to determine a diagnosis. This can be performed surgically or, more commonly, by a radiologist using a less invasive procedure that involves a hollow needle and image-guidance. Image-guided needle biopsy is not designed to remove the entire lesion but to obtain a small sample of the abnormality for further analysis.
Image-guided biopsy is performed by taking samples of an abnormality under some form of guidance such as ultrasound, MRI or mammography.
In ultrasound-guided breast biopsy, ultrasound imaging is used to help guide the radiologist's instruments to the site of the abnormal growth.
Before using for the first time, perform needle path verification to verify system and needle guide relations. To avoid any injury to the patient, please observe the following:
1. Refer to system manual for proper procedure.
2. Before verifying, ensure all parts are in good condition.
3. Ensure the needle guide and the needle have been installed correctly.
4. Use a needle suitable for the biopsy and the needle guide.
5. Use proper needle length to reach target area.
6. Carefully insert the needle to avoid bending.
7. Use a straight, new, sterile needle for each verification procedure to help predict the needle's orientation accurately.
8. The guidelines are only used to indicate the expected path of the needle.
9. Do not use the needle guide if the needle does not follow the intended path.
10. The needle used for this needle path verification must not be used for the actual procedure.
Company Details
Business Type:
Distributor/Wholesaler,Exporter,Trading Company,Seller
Year Established:
2014
Total Annual:
5,000,000-10,000,000
Employee Number:
50~60
Ecer Certification:
Active Member
Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex... Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex...
Get in touch with us
Leave a Message, we will call you back quickly!