Payment Terms | L/C, T/T, Western Union,Paypal |
Supply Ability | 20000Pcs per month |
Delivery Time | 1-30 days upon order quantity |
Packaging Details | Relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable. |
Indicators | LED display,2LEDs indicating trip, alert |
Output type | 1 C/O for trip,1 C/O for alert |
Operating voltage frequency | 50/60Hz |
Operating current range | 1-10A,5-50A,10-100A,20-200A |
Protective functions | short-circuit, locked-rotor, overcurrent, undervurrent, phase loss, phase unbalance, overvoltage,undervoltage, earth fault |
Optional functions | RS-485 communication port 4-20 mA analog output |
Brand Name | GINRI |
Model Number | WDB-1FMT |
Certification | CE,CCC |
Place of Origin | CHINA |
View Detail Information
Explore similar products
380 Volt Overcurrent Current Balance Relay Integrative Structure For Blowers
Phase Unbalance Current Monitoring Relay Integrative Structure For Compressors
Fans current limiting relay , 40A Phase Failure Protection Relay Integrative
Overload Current Monitoring Relay 1 NC SCR Output Contact LED Indication
Product Specification
Payment Terms | L/C, T/T, Western Union,Paypal | Supply Ability | 20000Pcs per month |
Delivery Time | 1-30 days upon order quantity | Packaging Details | Relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable. |
Indicators | LED display,2LEDs indicating trip, alert | Output type | 1 C/O for trip,1 C/O for alert |
Operating voltage frequency | 50/60Hz | Operating current range | 1-10A,5-50A,10-100A,20-200A |
Protective functions | short-circuit, locked-rotor, overcurrent, undervurrent, phase loss, phase unbalance, overvoltage,undervoltage, earth fault | Optional functions | RS-485 communication port 4-20 mA analog output |
Brand Name | GINRI | Model Number | WDB-1FMT |
Certification | CE,CCC | Place of Origin | CHINA |
High Light | current control relay , motor current monitoring relay |
Pumps Under Current Protection Relay With Fault Recording 50/60 Hz WDB-1FMT
First, the basic principles of selection
Today, there are no uniform standards for motor protection products on the market, and the model specifications are varied. Manufacturers in order to meet the different needs of users derive a lot of series of products, a wide range of types of users to bring a lot of inconvenience to the user selection, the user should fully consider the actual needs of motor protection in the selection, a reasonable choice of protection and protection To achieve a good protection effect, to improve the reliability of equipment operation, reduce unplanned parking, reduce accident losses.
Second, the basic method of selection
(a) Conditions related to selection:
The selection of motor protection has a reasonable matching relationship between the motor and the protector. The following provides several protection-related conditions and factors, which provide reference for the selection of the user.
1 . Motor: We must first understand the model specifications, motor functional characteristics, protection type, rated voltage, rated current, rated power, power frequency, insulation level and so on. These contents can basically provide reference for the user how to correctly use and maintain and select protectors.
2 . Environmental conditions: Mainly refers to normal temperature, high temperature, cold, corrosion, vibration, sand, altitude, and electromagnetic pollution.
3 , the use of motor: mainly refers to the characteristics of the requirements of mechanical equipment, such as fans, pumps, air compressors, lathes, oil field pumping units and other mechanical characteristics of the load.
4 . Control system: The control modes include manual, automatic, local control, remote control, independent stand-alone operation, and centralized production line control. The starting methods include direct, step-down, star delta, frequency sensitive rheostat, frequency converter, and soft start.
5 . Other aspects: The user's management of on-site production monitoring is more casual or rigorous, and the severity of non-normal downtime impact on production.
There are many relevant factors related to the selection of the protector, such as the installation location, power supply conditions, and the power distribution system, etc.; it is also necessary to consider whether the newly purchased motor protection configuration, or the motor protection upgrade, or the accident motor The perfection of protection, etc.; also consider the difficulty of changing the motor protection mode and the degree of impact on the production; need to comprehensively consider the selection and adjustment of the protector according to the actual working conditions at the site.
♦ Features
-- Integrative structure or Separate structure-- Built-in LED and keypad afford a precise,digital setting-- Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage-- Earth fault (should couple with ZCT) -- Fault recording -- RS-485 communication port (optional) -- 4-20 mA analog output (optional) unbalance,overvoltage,undervoltage -- 2 C/O output contacts, one for trip,one for alert
♦ Protective Functions
-- Short-circuit -- Locked-rotor -- Overcurrent -- Undercurrent
-- Phase loss -- Phase unbalance -- Overvoltage -- Undervoltage
-- Ground fault
♦ Typical Applications
• Pumps • Fans • Blowers • Motors • Compressors
♦ Technical data
Type | WDZ-1Z | WDZ-1F | WDZ-1F2 |
Rated voltage | 220VAC,380VAC ,50/60Hz | ||
Current range | 1-10A,5-50A,10-100A,20-200A,80-400A,400-600A,600-800A | ||
Protective functions | short-circuit, locked-rotor, overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage, earth fault | ||
Optional functions |
RS-485 communication port |
||
Indicators | LED indicating voltage,current,operation status | ||
Output contacts | 1 C/O for trip,1 C/O for alert | ||
Contact capacity | 3A 380VAC | ||
Dimensions (H x W x D) | 118×54×135mm | 101×54×77mm(LED part) | 101×54×77mm(LED part) |
Mounting | screw fixing | LED part panel mounted and CT part screw fixing |
LED part panel mounted |
Company Details
Business Type:
Manufacturer
Year Established:
1995
Employee Number:
50~100
Ecer Certification:
Active Member
GINRI POWER AUTOMATION CO.,LTD. is a professional production voltage phase sequence protection device (and name: three-phase power monitor), and PLC output zoom Board, and smart type motor integrated protection device, and industrial parts manufacturers, technology development team in elevator indus... GINRI POWER AUTOMATION CO.,LTD. is a professional production voltage phase sequence protection device (and name: three-phase power monitor), and PLC output zoom Board, and smart type motor integrated protection device, and industrial parts manufacturers, technology development team in elevator indus...
Get in touch with us
Leave a Message, we will call you back quickly!