China factories

China factory - Shenzhen Xinhe'an Technology Co., Ltd.

Shenzhen Xinhe'an Technology Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Non Polarized 2 Wire Smoke Alarm 105g For Conventional Detection Alarm System
China Non Polarized 2 Wire Smoke Alarm 105g For Conventional Detection Alarm System

  1. China Non Polarized 2 Wire Smoke Alarm 105g For Conventional Detection Alarm System
  2. China Non Polarized 2 Wire Smoke Alarm 105g For Conventional Detection Alarm System

Non Polarized 2 Wire Smoke Alarm 105g For Conventional Detection Alarm System

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 10000PCS/Month
Delivery Time 3 Working days
Packaging Details 100pcs/carton
Product Type Conventional Fire Alarm System
Working Voltage 9 to 28VDC
Alarm Output Sound/Light
Detection Method Smoke
Wired 2 Wired , Non-polarized
Specification D103mm, H55mm
Detection Range 50m²
Remote Monitoring With Remote Function
Brand Name XHA
Model Number XHA8015
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 10000PCS/Month
Delivery Time 3 Working days Packaging Details 100pcs/carton
Product Type Conventional Fire Alarm System Working Voltage 9 to 28VDC
Alarm Output Sound/Light Detection Method Smoke
Wired 2 Wired , Non-polarized Specification D103mm, H55mm
Detection Range 50m² Remote Monitoring With Remote Function
Brand Name XHA Model Number XHA8015
Certification CE Place of Origin China
High Light Non Polarized 2 Wire Smoke AlarmCE 2 Wire Smoke Alarm2 Wire Smoke Alarm 105g

2 Wire Smoke Alarm For Conventional Detection Alarm System

 



Introduction

The primary purpose of a conventional smoke detector is to provide early warning of a potential fire by detecting the presence of smoke and triggering an audible alarm to alert occupants. This allows people to evacuate the area and call emergency services if necessary. it can be compartible with other brand conventional panel.

 

The main functions of a conventional smoke detector are:

Smoke Detection:
The smoke detector uses photoelectric sensor to detect the presence of smoke particles in the air.
The sensor reacts to the changes in the air caused by smoke, triggering the alarm.


Alarm Activation:
When smoke is detected, the smoke detector activates an audible alarm, such as a loud beeping or buzzing sound.
The alarm is intended to alert occupants to the potential fire hazard, prompting them to evacuate the area.


Power Supply:
Conventional smoke detectors can be powered by a hardwired connection to the building's electrical system.

Testing and Maintenance:
Smoke detectors require regular testing to ensure they are functioning correctly.
Periodic cleaning is also necessary to maintain their reliability.

 



Parameters

Product Name  Smoke Detector Rated operational voltage 9 to 28VDC Volts Non-polarized
Adjustable Sensitivity 1.06±.26%FT Static current ≤60µA @ 24 VDC
Alarm current 30mA @ 24 VDC Work temperature -10°C~+50°C
Certification CE Humidity ≤95%.
Size  103*103*55mm Weight 105g

 

 

 

Installation

 


INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

Remove power from initiating-device circuits before installing detectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.

      Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.

      

 

 


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector

 

 



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.




 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Year Established:

    2001

  • Total Annual:

    4300000-7140000

  • Employee Number:

    40~50

  • Ecer Certification:

    Verified Supplier

We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Xinhe'an Technology Co., Ltd.
  • 406,Jude Building,Zhengfeng South Road,Fuyong Street,Bao'An District, Shenzhen City, Guangdong Province. China,518103
  • https://www.xhafiresafety.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement