GF106T Smart Electrical Test Equipment CT PT Testing With Current Injection

  1. MOQ: 1 Set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, Western Union, MoneyGram, L/C
Supply Ability 200 Sets/Month
Delivery Time 3-4 weeks
Packaging Details Standard Industrial Case
Name GF106T Smart Electronic Test Equipment for CT PT Testing with Current Injection function
Accuracy 0.2%, 0.5%
Excitation voltage output 0-2500Vrms,
Excitation current output 0-5Arms (20A peak-value)
Large current output 0-1000A
Overall dimension (L x W x H) (mm) Overall dimension (L x W x H) (mm)
Brand Name GFUVE
Model Number GF106T-2
Certification ISO CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, MoneyGram, L/C Supply Ability 200 Sets/Month
Delivery Time 3-4 weeks Packaging Details Standard Industrial Case
Name GF106T Smart Electronic Test Equipment for CT PT Testing with Current Injection function Accuracy 0.2%, 0.5%
Excitation voltage output 0-2500Vrms, Excitation current output 0-5Arms (20A peak-value)
Large current output 0-1000A Overall dimension (L x W x H) (mm) Overall dimension (L x W x H) (mm)
Brand Name GFUVE Model Number GF106T-2
Certification ISO CE Place of Origin CHINA
High Light electronic test equipmentelectronic measurement equipment

 

GF106T Smart Electronic Test Equipment for CT PT Testing with Current Injection function

It is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

Portable CT PT analyzer brings a lot of convinent for engieers to test CT on feild. Easy opearte and bring.

GFUVE GF106T is the basic model of CT PT analyzer, which used generate large curren and voltage for testing Ct and PT. This Model is economy, working stable .

 

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity
4. 5% and 10% error curve 4. Withstand test of power frequency alternating current
5. Current Injecting 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Withstand test of power frequency alternating current 7. Actual secondary load test 
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test 
10. Resistance test 

PARAMETERS

Electrical parameters
Accuracy 0.2%, 0.5%
Power supply AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output 0-2500Vrms,
Excitation current output 0-5Arms (20A peak-value)
Large current output 0-1000A
Electrical parameters - continued
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurement Range 0.1-300Ω
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurement Accuracy ±4min
Resolution 0.01min
CT ratio error measurement Range ≤25000A/5A(5000A/1A)
Accuracy ≤0.5%
PT ratio error measurement Range 1-500KV
Accuracy ≤0.5%
Standards 
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters 
Overall dimension (L x W x H) (mm) 400 x 250 x 250
Weight (kg) ≤22
Environmental conditions 
Relative humidity 90RH%
Operating temperature -10°C to +40°C
Altitude ≤1000m

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    $100,000,000-$150,000,000

  • Employee Number:

    300~350

  • Ecer Certification:

    Active Member

Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core... Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
  • Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
  • https://www.zerosequencecurrenttransformer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement