Packaging Details | Wooden Package |
Delivery Time | 5-8 work days |
Supply Ability | 200 pieces |
Payment Terms | L/C D/A D/P T/T Western Union |
Name | Digital IZOD&Charpy Impact tester |
Power | AC220V±10% 50HZ |
Impact speed | 2.9m/s |
Pendulum center distance | 335mm |
Test standard | ISO 179 |
Model Number | LR-A004 |
Place of Origin | China |
Brand Name | Lonroy |
Certification | CE ISO ASTM |
View Detail Information
Explore similar products
ISO1133 Plastic Melt Flow Index Tester Machine MFR / MVR Tester For ABS PS PE
ISO1133 Melt Flow Index Tester Melt Flow Rate (MFR) Test
Touched Screen Melt Flow Index Tester MFR and MVR Method ASTM D1238
ISO 1133 Fully Automatic Melt Flow Index Tester MFI Test Equipment
Product Specification
Packaging Details | Wooden Package | Delivery Time | 5-8 work days |
Supply Ability | 200 pieces | Payment Terms | L/C D/A D/P T/T Western Union |
Name | Digital IZOD&Charpy Impact tester | Power | AC220V±10% 50HZ |
Impact speed | 2.9m/s | Pendulum center distance | 335mm |
Test standard | ISO 179 | Model Number | LR-A004 |
Place of Origin | China | Brand Name | Lonroy |
Certification | CE ISO ASTM | ||
High Light | digital plastic test machine ,digital plastic testing machine ,astm d256 plastic test machine |
ISO179 ASTM D256 IZOD& Charpy Impact Tester
This instrument for new multi-function IZOD&Charpy impact tester, without having to remove the jig and sample fixed frame, cantilever beam, the test method for automatic switch, easy to use, simple operation, high measurement precision, it is mainly used for hard thermoplastic moulding and extrusion materials, rigid thermosetting molding materials as well as the fiber reinforced thermosetting and thermoplastic composites non-metallic materials, such as the determination of impact toughness.
2. Character
cantilever beam, one-piece shock, do not need to remove the clamp and fixed sample
intelligent controller has high precision, and is equipped with LCD display, can be intuitive, accurate reading data
the first domestic use carbon fiber beam (has applied for patent), on the direction of impact, improve the rigidity of materials, and will impact the quality of concentrated in the largest pendulum on the center of mass of truly no vibration impact test, and increase the service life.
imported high resolution digital encoder, Angle test precision is higher and more stable
aerodynamic impact hammer and imported ball bearing, greatly reduced the mechanical friction loss
automatically calculate the final result, test data can be stored 24 group data and averaging
can choose Chinese and English operation interface, test results can choose J/m, KJ / ㎡, kg - cm/cm, ft - ib/in etc
Internal microtyping of the printing and testing data
3. Test standard
ISO179-2000 "plastics - determination of impact strength of the simply supported beam with hard material,
GB/T 21189 < plastic beam and cantilever beam and tensile impact test with a pendulum impact testing machine test >
GB/T1043-2008 "the hard plastic beam impact test method"
JB/T8762-1998 plastic beam impact testing machine,
GB/T 18743-18743 "with thermoplastic fluid conveying pipe beam impact test method" (applicable to pipe)
ISO180-2000 "plastics - determination of hard material cantilever beam impact strength
GB/T1843-2008 "the hard plastic cantilever beam impact test method"
JB/T8761-1998 plastic cantilever beam impact testing machine,
ASTM D256-2010 "test method for determination of plastic the IZOD pendulum impact strength,
GB - T13525-1992 "plastic tensile impact test method for performance"
4.Technical Specifications
Name |
Digital IZOD&Charpy Impact tester |
|
Model |
LR-A004-5D |
|
IZOD Specification |
Impact energy |
5.5J,2.75J |
Elevation in advance |
150°(accuracy 0.01°) |
|
impact speed |
3.5m/s |
|
Pendulum center distance |
335mm |
|
The impact blade radius of the cantilever beam |
R=0.8±0.2mm |
|
Impact blade to the surface distance of the tongs |
22mm±0.05mm |
|
Centring sample piece |
1pcs |
|
Charpy specification |
Elevation in advance |
150° |
Impact energy |
1J,2J,4J,5J |
|
Impact speed |
2.9m/s |
|
Pendulum center distance |
230mm |
|
Beam support distance |
40mm,60mm(or 62mm),70mm,95mm |
|
Chapry Impact blade radius |
R=2mm±0.5mm |
|
Impact blade Angle |
30°±1° |
|
Centring sample piece |
1pcs |
|
Power |
AC220V±10% 50HZ |
Company Details
Business Type:
Manufacturer,Seller,Exporter,Agent
Year Established:
2008
Total Annual:
$5 million -$8 million
Employee Number:
80~200
Ecer Certification:
Verified Supplier
Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong, is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to providing excellent tes... Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong, is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to providing excellent tes...
Get in touch with us
Leave a Message, we will call you back quickly!